Aortic valve assessment by cardiac tomography: application in clinical practice
DOI:
https://doi.org/10.47487/apcyccv.v6i3.516Keywords:
Aortic Valve, Cardiac Tomography, Aortic Stenosis, Endocarditis, Aortic Valve InsufficiencyAbstract
Aortic valve disease is a highly prevalent and clinically significant condition in the general population. Cardiac computed tomography (CT) has emerged as a widely available imaging modality that provides high-resolution static and dynamic information, enabling comprehensive evaluation of valve anatomy and function. This technique complements echocardiography and other imaging tools, adding incremental value to clinical decision-making. Its principal applications include identifying the etiology of valvular disease, grading severity, and assessing adjacent structures, all of which are critical for therapeutic planning. This non-systematic review synthesizes the evidence on the role of CT in the assessment of the aortic valve, focusing on aortic stenosis, aortic regurgitation, infective endocarditis, and postoperative evaluation. The current body of evidence underscores the expanding role of CT in the integrated diagnosis and longitudinal management of aortic valve disease.
Downloads
References
Osnabrugge RLJ, Mylotte D, Head SJ, Van Mieghem NM, Nkomo VT, LeReun CM, et al. Aortic stenosis in the elderly. J Am Coll Cardiol. 2013;62(11):1002-12. doi: 10.1016/j.jacc.2013.05.015.
Morís C, Pascual I, Avanzas P. Will TAVI be the standard of care in the treatment of aortic stenosis? Rev Esp Cardiol (Engl Ed). 2016;69(12):1131-4. doi: 10.1016/j.rec.2016.09.012.
Carroll JD. TAVR prognosis, aging, and the second TAVR tsunami. J Am Coll Cardiol. 2016;68(15):1648-50. doi: 10.1016/j.jacc.2016.08.005.
Chen JJS, Jeudy J, Thorn EM, White CS. Computed tomography assessment of valvular morphology, function, and disease. J Cardiovasc Comput Tomogr. 2009;3(1 Suppl):S47-56. doi: 10.1016/j.jcct.2008.10.017.
Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH. Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv. 2008;1(1):74-81. doi: 10.1161/CIRCINTERVENTIONS.108.780858.
Weir-Restrepo D, Mesa-Maya MA, Carvajal-Vélez MI, Abad-Díaz P, Duque-González L. Válvula aórtica cuadricúspide: una revisión de la literatura. REC Cardio Clinics. 2025;60(1):53-8. doi: 10.1016/j. rccl.2024.07.006.
Abbara S, Blanke P, Maroules CD, Cheezum M, Choi AD, Han BK, et al. SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr. 2016;10(6):435-49. doi: 10.1016/j.jcct.2016.10.002.
Henzler T, Carrascosa P, Ko BS, Rubinshtein R. Principles of cardiac CT image acquisition. In: Schoepf UJ, editor. CT of the heart. Totowa: Humana Press; 2019. p. 69-85.
Guler EC, Yam Y, Jia K, Mais HE, Hossain A, Chow BJW, et al. Effectiveness of point-of-care oral ivabradine for cardiac computed tomography. J Cardiovasc Comput Tomogr. 2021;15(3):226-31. doi: 10.1016/j.jcct.2020.09.006.
Scholtz JE, Ghoshhajra B. Advances in cardiac CT contrast injection and acquisition protocols. Cardiovasc Diagn Ther. 2017;7(5):439-51. doi: 10.21037/cdt.2017.06.07.
Clavel MA, Malouf J, Messika-Zeitoun D, Araoz PA, Michelena HI, Enriquez-Sarano M. Aortic valve area calculation in aortic stenosis by CT and Doppler echocardiography. JACC Cardiovasc Imaging. 2015;8(3):248-57. doi: 10.1016/j.jcmg.2015.01.009.
Zeb I, Uqaily R, Gonuguntla K, Ludhwani D, Abdelhaleem A, Leipsic J, et al. Multimodality assessment of high- vs. low-gradient aortic stenosis using echocardiography and cardiac CT. J Cardiovasc Comput Tomogr. 2023;17(6):421-8. doi: 10.1016/j.jcct.2023.09.002.
Mittal TK, Reichmuth L, Bhattacharyya S, Jain M, Baltabaeva A, Rahman Haley S, et al. Inconsistency in aortic stenosis severity between CT and echocardiography: prevalence and insights into mechanistic differences using computational fluid dynamics. Open Heart. 2019;6(2):e001044. doi: 10.1136/openhrt-2019-001044.
Kim WK, Praz F, Blumenstein J, Liebetrau C, Gaede L, Van Linden A, et al. Transfemoral aortic valve implantation of Edwards SAPIEN 3 without predilatation. Catheter Cardiovasc Interv. 2017;89(1):E38-43. doi: 10.1002/ccd.26464.
Scalia IG, Farina JM, Padang R, Jokerst CE, Pereyra M, Mahmoud AK, et al. Aortic valve calcium score by computed tomography as an adjunct to echocardiographic assessment: a review of clinical utility and applications. J Imaging. 2023;9(11):250. doi: 10.3390/ jimaging9110250.
Gać P, Jaworski A, Grajnert F, Kicman K, Trejtowicz-Sutor A, Witkowski K, et al. Aortic valve calcium score: applications in clinical practice and scientific research: a narrative review. J Clin Med. 2024;13(14):4064. doi: 10.3390/jcm13144064.
Kramer B, Vekstein AM, Bishop PD, Lowry A, Johnston DR, Kapadia S, et al. Choosing transcatheter aortic valve replacement in porcelain aorta: outcomes versus surgical replacement. Eur J Cardiothorac Surg. 2023;63(5):ezad057. doi: 10.1093/ejcts/ezad057.
Pawade T, Sheth T, Guzzetti E, Dweck MR, Clavel MA. Why and how to measure aortic valve calcification in patients with aortic stenosis. JACC Cardiovasc Imaging. 2019;12(9):1835-48. doi: 10.1016/j.jcmg.2019.01.045.
Intorcia A, Ambrosini V, Capasso M, Granata R, Magliulo F, Carbone GL, et al. Management of transcatheter aortic valve implantation and complex aorta anatomy: the importance of pre-procedural planning. Int J Environ Res Public Health. 2022;19(8):4763. doi: 10.3390/ijerph19084763.
Chieffo A, Giustino G, Spagnolo P, Panoulas VF, Montorfano M, Latib A, et al. Routine screening of coronary artery disease with computed tomographic coronary angiography in patients undergoing transcatheter aortic valve replacement. Circ Cardiovasc Interv. 2015;8(7):e002025. doi: 10.1161/CIRCINTERVENTIONS.114.002025.
Bennett CJ, Maleszewski JJ, Araoz PA. CT and MR imaging of the aortic valve: radiologic-pathologic correlation. Radiographics. 2012;32(5):1399-420. doi: 10.1148/rg.325115727.
Siani A, Perone F, Costantini P, Rodolfi S, Muscogiuri G, Sironi S, et al. Aortic regurgitation: a multimodality approach. J Clin Ultrasound. 2022;50(8):1041-50. doi: 10.1002/jcu.23299.
Patel KP, Vandermolen S, Herrey AS, Cheasty E, Menezes L, Moon JC, et al. Cardiac computed tomography: application in valvular heart disease. Front Cardiovasc Med. 2022;9:849540. doi: 10.3389/fcvm.2022.849540.
Delgado V, Ajmone-Marsan N, de Waha S, Bonaros N, Brida M, Burri H, et al. 2023 ESC Guidelines for the management of endocarditis. Eur Heart J. 2023;44(39):3948-4042. doi: 10.1093/eurheartj/ehad193.
Mgbojikwe N, Jones SR, Leucker TM, Brotman DJ. Infective endocarditis: beyond the usual tests. Cleve Clin J Med. 2019;86(8):559- 67. doi: 10.3949/ccjm.86a.18120.
Khalique OK, Veillet-Chowdhury M, Choi AD, Feuchtner G, LopezMattei J. Cardiac computed tomography in the contemporary evaluation of infective endocarditis. J Cardiovasc Comput Tomogr. 2021;15(4):304-12. doi: 10.1016/j.jcct.2021.02.001.
Litmanovich DE, Kirsch J. Computed tomography of cardiac valves: review. Radiol Clin North Am. 2019;57(1):141-64. doi: 10.1016/j. rcl.2018.08.011.
Ghersin E, Martínez CA, Singh V, Fishman JE, Macon CJ, Runco Therrien JE, et al. ECG-gated MDCT after aortic and mitral valve surgery. AJR Am J Roentgenol. 2014;203(6):W596-604. doi: 10.2214/AJR.13.12404.

Downloads
Published
Issue
Section
License
Copyright (c) 2025 The journal is headline of the first publication, then the author giving credit to the first publication.

This work is licensed under a Creative Commons Attribution 4.0 International License.