Transcatheter pulmonary valve replacement with the Myval valve in patients who have undergone surgery for tetralogy of Fallot: Report of the first three cases at a tertiary care hospital

Authors

DOI:

https://doi.org/10.47487/apcyccv.v7i4.621

Keywords:

Heart Defect, Congenital, Tetralogy of Fallot, Cardiac Catheterization, Doppler Echocardiography, Pulmonary Valve, Pulmonary Valve Insufficiency

Abstract

Percutaneous pulmonary valve implantation is an alternative to surgical replacement for patients with right ventricular outflow tract dysfunction—such as those who have undergone surgery for tetralogy of Fallot, truncus arteriosus, or pulmonary atresia with ventricular septal defect and a right ventricle-to-pulmonary artery conduit, as well as patients with severe pulmonary regurgitation following pulmonary valvuloplasty. In our country, the Melody® balloon-expandable valve (Medtronic), the Pulsta™ self-expanding valve, and, more recently, the Myval™ balloon-expandable valve are currently marketed. The Myval™ is primarily used for aortic valve replacement but is also used for pulmonary valve replacement or valve-in-valve replacement of the mitral or tricuspid valve. We present the first three cases of Myval™ pulmonary valve implantation performed in Peru in adolescent patients with right ventricular outflow tract dysfunction following surgery for tetralogy of Fallot.

Downloads

Download data is not yet available.

References

Salas-Mera D, Abelleira Pardeiro C, Balbucid Domingo EJ, Sobrino Baladrón A, Zunzunegui Martínez JL, Sarnago Cebada F, et al. The PULSTA valve in native right ventricular outflow tract: initial experience in 3 Spanish hospitals. REC Interv Cardiol [Internet]. 2024;6(2):89–96.

McCarthy EK, Georgiev S, Zhang Y, Boucek ME, Johnson KC, Jaggi A, et al. Long-term outcomes after Melody transcatheter pulmonary valve implant in patients weighing ≤30 kg. JACC Cardiovasc Interv. 2026;19(1):80–92.

Al Nasef M, Erdem A, Aldudak B, Yildirim A, Hijazi ZM, Boudjemline Y, et al. Multicenter experience for early and mid-term outcome of MyVal transcatheter pulmonary valve implantation. Pediatr Cardiol. 2024;45(3):570–9.

Ashfaq A, Faateh M, Shahanavaz S. Percutaneous and surgical pulmonary valve replacement options in adult congenital heart disease: A review. Curr Treat Options Pediatr. 2024;10(4):167–77.

Bonhoeffer P, Boudjemline Y, Saliba Z, Merckx J, Aggoun Y, Bonnet D, et al. Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction. Lancet. 2000;356(9239):1403–5.

Mussayev A, Alimbayev S, Tanaliev N, Kuanyshbek A, Marat A, Lesbekov T, et al. Case report: Transcatheter tricuspid valve-in-valve implantation using novel balloon-expandable aortic valve with 1 year follow-up. Front Cardiovasc Med.2023;10:1152280.

Blasco-Turrión S, Serrador-Frutos A, Jose J, Sengotuvelu G, Seth A, Aldana VG, et al. Transcatheter mitral valve-in-valve implantation with the balloon-expandable Myval device. J Clin Med. 2022;11(17):5210.

De Torres-Alba F, Kaleschke G, Baumgartner H. Impact of percutaneous pulmonary valve implantation on the timing of reintervention for right ventricular outflow tract dysfunction. Rev Esp Cardiol (Engl Ed). 2018;71(10):838–46.

Suradi HS, Hijazi ZM. Percutaneous pulmonary valve implantation. Glob Cardiol Sci Pract. 2015;2015(2):23.

Demkow M, Biernacka EK, Spiewak M, Kowalski M, Siudalska H, Wolski P, et al. Percutaneous pulmonary valve implantation preceded by routine prestenting with a bare metal stent. Catheter Cardiovasc Interv. 2011;77(3):381–9

Tezza M, Witsenburg M, Nieman K, van de Woestijne PC, Budde RPJ. Cardiac CT to assess the risk of coronary compression in patients evaluated for percutaneous pulmonary valve implantation. Eur J Radiol. 2019;110:88–96.

Faccini A, Giugno L, Carminati M, Butera G. Percutaneous pulmonary valve implantation contraindicated by severe aortic regurgitation due to left coronary sinus deformation. Circ J. 2018;82(8):2212.

Rebonato M, Pilati M, Milani SM, Bonnet D, Pascall E, Jones M, et al. BeGraft aortic stents: A European multi-centre experience reporting acute safety and efficacy outcomes for the treatment of vessel stenosis in congenital heart diseases. J Cardiovasc Dev Dis. 2024;11(7):192.

Morgan GJ, Sadeghi S, Salem MM, Wilson N, Kay J, Rothman A, et al. SAPIEN valve for percutaneous transcatheter pulmonary valve replacement without “pre-stenting”: A multi-institutional experience. Catheter Cardiovasc Interv. 2019;93(2):324–9.

Karsenty C, Malekzadeh-Milani S, Fraisse A, Gewillig M, Bonnet D, Aldebert P, et al. Right ventricular outflow tract prestenting with AndraStent XXL before percutaneous pulmonary valve implantation. Arch Cardiovasc Dis. 2020;113(2):113–20.

Manica JLL, Rossi Filho RI, Pedra CAC, Caovilla FV, Chamié F, Pilla CB, et al. Percutaneous pulmonary valve implantation in native right ventricular outflow tract using MyValTM without pre-stenting. Health Sci Rep. 2025;8(4):e70598.

Odemis E, Yenidogan I. First experiences with Myval Transcatheter Heart Valve System in the treatment of severe pulmonary regurgitation in native right ventricular outflow tract and conduit dysfunction. Cardiol Young. 2022;32(10):1609–15.

Guzeltas A, Duras E, Balik RS, Cilsal E, Ugan Atik S, Sahin M, et al. Early-term outcomes of percutanous pulmonary valve implantation with the Meril’s Myval pulmonary valve-single center experience from turkey. Catheter Cardiovasc Interv. 2026;107(2):629–38.

Downloads

Published

2026-10-21

Issue

Section

Case reports